Power supply for digital load cells
Protection classes per DIN EN 60529
IP68, IP69:
Dust-proof and leak-proof against water, with harmful
effects when immersed, (0.5 m water depth, 1,000 h)
and water jets (high pressure and temperature).
IP66:
Dust-proof and leak-proof against strong water jets.
Installation position Cable entry from below
Clamping area screw connection M16 5…9.5 mm
Supply voltage UAC = 100…240 V ±10%, 50/60 Hz
Max. power consumption 35 VA
Fuse 2× 1.6 AT
Output voltage UDC = 24 V
Pressure equalization Stainless steel pressure equalization element
Material of the junction box High-grade stainless steel 1.4301 (X5CrNi 18-10) according
to EN 10088-3, AISI 304, JIS SUS304
Surface of the junction box 2R according to DIN EN 10088-2 (cold-rolled, bright
annealed, flat, blank, reflective)
Net weight 0.97 kg
Shipping weight 1.22 kg
Service temperature area -30°C…+80°C
Service temperature area, in explosion-prone area -20°C…+50°C
Storage temperature range -30°C…+80°C
Cable screw connections Metal Ex EMC cable screw connections
Ex-connection values See Chapter 8.1.
Moisture <95 %, non-condensing (per IEC 68-2)
Seal EMC seal
Cable length Supply cable PR 6124/xxP for
mains supply PR 6024/62S: max. 200 m
Data cable PR 6124/xxD for device: max. 300 m
Service temperature area of cables Supply cable PR 6124/xxP: -30°C…+90°C
Data cable PR 6124/xxD: -30°C…+90°C